MCO-5AC-PE CO2 incubator

Personal Series Compact CO2 Incubator

When arranged in triple stackable configurations, this unit meets GLP requirements by helping to avoid patient-to-patient cross contamination in individualized patient-specific clinical incubation applications. 

Improved Temperature Stability with D.H.A. System
P.I.D. controlled 3-way heaters plus Panasonic's proprietary D.H.A. (Direct Heat and Air jacket) provides a high-precision temperature environment, and minimizes the risk of condensation now and in the future. The Panasonic D.H.A. System is patented with U.S. Patent Number 5519188

Panasonic Biomedical also offers two other sizes of the same type C02 Incubator:

MCO-170AIC-PE
MCO-18AC-PE

  • Preventive Contamination Control
  • Ergonomic Design
  • Field-reversible Door
  • Active Background Contamination Control
  • Heat Decontamination Not Required
  • High Performance In Vitro Modeling
  • Automatic CO2 Cylinder Switchover System
  • Ergonomic Design (Compact, Triple Stacking)
  • TC Sensor System
  • Compact, triple stacking
  • Single chamber
  • Active Background Contamination Control
  • Patented Direct Heat and AIR Jacket Heating System
  • Panasonic inCu saFe copper-alloy-stainless interior, shelves and plenum
  • Panasonic SafeCell UV continuous active background ultraviolet light sterilization
  • Water Level Sensor
  • Automatic Gas Cylinder Switchover System (Optional)
  • In Vitro Fertilization Applications

Product Specification

Dimensions 
External dimensions (W x D x H)480 x 548 x 575 mm
Internal dimensions (W x D x H)350 x 378 x 375 mm
volume49 litres
net weight49 kg
Technical Data 
Power supply230 V
Frequency50 Hz
Noise Level24 dB
Insulation materialPUF
Performance 
Temperature sensorThermistor
CO2 sensorTC
O2 sensor 
Temp control range and fluctuationAmbient temp +5 ~ +50, ±0.1 °C
Temperature uniformity±0.25 4) °C
CO2 control range and fluctuation0 ~ 20, ±0.15 %
O2 control range-
Humidity control range and fluctuation95, ±5 %RH
Light control range-
Alarms 
Power failure 
Out of temperature settingV-B-R
High temperatureV-B-R
Out of CO2 settingV-B-R
Out of humidity setting 
Door open 
Water level 
General 
Exterior materialPainted steel
Colour (exterior)Bio-gray
Cabinet material (interior)SS copper alloyed
Outside lid/door1
Reversable door 
Inside lid/door1
Lid / outside door lock 
Shelves3
Max. load per shelf4 kg
Max. total load12 kg
Max. Shelf capacity6
Access port1
- positionrear
- diameter30 ¯ mm

Accessories

Shelfs and brackets (InCu saFe)MCO-30ST-PW
Roller baseMCO-5RB-PW
CO2-gas pressure regulatorMCO-100L-PW
Automatic CO2 switchover systemMCO-5GC-PW
UV-system kitMCO-18UVS-PW
Stacking kitStandard
Digital interfaceMTR-480-PW
Analogue interfaceMCO-420MA-PW
>Instruction Manual MCO-5AC-PE
Download
>Professional Co2 and O2 Co2 Incubators Brochure
Download
>Part List MCO-5AC-PE
Download